MULTI Test
Portable digital multimeter. MEASURES mA, mV, V, A, Hz, Ohm, uF, ºC (AC/DC).
Request more information
Description
Portable digital multimeter. MEASURES mA, mV, V, A, Hz, Ohm, uF, ºC (AC/DC). Component tester. K thermocouple probe included. Power supply: internal 9V battery.
Data sheet
Discharge
Request a quote, a technical consultation or product information
Name
Company
E-MAIL
Phone
Affair
Budget request
Product information
Technical consultation
Message
SEND
Other sensors
RESIS-42R
Low value resistance converter to 4/20mA (Active/Passive) Input Low value resistance (5, 10 Ohm,..) Built-in datalogger Output: 0-4/20mA Power supply: 24VDC
View product
AMPER Plus
Universal isolator of alternating sinusoidal current 0/1A, 0/5A, 0/10A (AC) Multiple output: 0/20mA or 4/20mA (Active / Passive), 0/10V, intermediate and INVERSE values. Dual power supply: 24VDC -115/230VAC.
View product
ADAPTA ENCODER 2
Isolator - amplifier - duplicator - adapter for 2 encoder channels. Up to 1MHz. (adapts differential signals to simple signals).
View product
DPF-CO2-ANCO2L
Indoor CO2 sensor, range up to 4000 ppm, analog output and relay alarm
View product
ISO-DUO-M10
3-way isolator input ± 0/10V, excitation (24V/20mA) isolated, output isolated ± 0/10V, Power supply 24VDC (20.. 30V) isolated * 2 channels *
View product
ISO-DUO-20EN
3-way isolator, input: 0-4/20mA (Active/Passive), output 0-4/20mA (with excitation to passive loops), isolated output: 0-4/20mA (Active) Power supply 24VDC (20.. 30V ) isolated * 2 channels*
View product
THERMO-PT-V
Pt100 temperature sensor converter Output: 0/10V.
View product
ISO2-DUO-420
Passive 4/20mA 2-way galvanic isolator. 2 channels (ISO2 DUO 420) Self-powered 24VDC.
View product
EXPANDI16
Expander from 1 digital signal to 16 digital outputs. Expandable to 32, 48, 64, .. for DIGIMUX16
View product
ISO-QUATTRO-42/10
Universal 2-way galvanic isolator/converter. 4 channels, Input: 4/20mA (Active/Passive), Output 0-10 VDC, Power: 10...30 VDC
View product
DP 120
Combined wind speed and direction sensor
View product
TPD710
Differential pressure transmitter. Measuring range up to 3MPa (30 Bar)
View product
IND32-PM
Process indicator format 32 x 74, LARGE FORMAT display, Pt100 input - Thermocouple - mA - Vcc - potentiometer
View product
MEDIA-4xRTD
Converter for averaging 4 RTD signals
View product
DIGI Cal Thermos
Pt100 generator with digital display Simulates 2 or 3 wire Pt100, range -50.. +400ºC Power supply 24.. 230VAC-DC (±15%) isolated
View product
TERMO-ISO-Plus
THERMOCOUPLE CONVERTER AND Pt100, Pt500, Pt1000, Ni100. 2, 3 or 4 WIRES, PROGRAMMABLE VIA PC
View product
HPS-LX
Wire displacement sensor, ranges from 11000 ….. 35000 mm, with output signal in 5 Kohm resistance, 0-5 / 10 Vdc, 4-20 mA, RS485 or pulses
View product
Weather vane-420-M12
Wind direction sensor for industrial use, with 4-20 mA output signal
View product
LIMIT-V Plus
Voltage limiter with adjustable limit input: 0/10V isolated output: 0/10V limited by adjustable internal front power supply 24.. 230VAC-DC (±15%) isolated
View product
DPK300.x
Dust concentration sensor
View product
DPK204
Solar radiation sensor, pyranometer
View product
AMPER Relay .5 / .16
AC current relay. Overload/underload.
View product
DPF-CO2-SCF
Indoor CO2 sensor, range up to 4000 ppm, analog output and digital alarm
View product
ISO2-DUO-42P
Isolator for passive collectors. Passive output 4/20mA, input: 4/20mA (for passive pickup) - 2 channels
View product
DPK402
Rain and/or snow detector
View product
ISO-viR-L42R
Galvanic isolator. Wireless configuration, Input: 0/10V - 0-4/20mA - RESISTANCE 0/4K, 10 linearization sections, Isolated output 4/20mA (Active / Passive) automatic, Power: 24VDC (10.. 30V)
View product
MUXU16
Multiplexer that statically switches 16 0/10V channels
View product
MUX4RTD-2
Universal multiplexer with 4 x 2-wire RTD (NTC 10K, PTC 1K, Pt1000, Pt100, ..) at the output of the same probe
View product
DUPLO-Pt-PLUS
Isolated Pt100 duplicator (supports pulsed signal) to Pt100 + 4/20mA and 0/10V
View product
HPS-Sxx
Wire displacement sensor, miniature size, ranges 250, 500, 750, 1000 mm
View product
TEMPO Relay
Multifunction timer relay
View product
ISO3-PAR-mini
3-way thermocouple galvanic isolator at 0-4/20mA and 0/10V. In narrow 6.2mm case
View product
ISO-10/42
Isolator-converter to active output 4/20mA, Input: 0-10 Vdc, Isolated output 0-4/20mA active, Power supply: 24VDC (20.. 30V) isolated
View product
ENERGY-PLUS
AC/DC MONOPHASE NETWORK ANALYZER (TRMS, Measurement of energy, voltage, intensity, power, frequency, ..
View product
DUPLO-M10
Duplicator - signal isolator 0/±10V input: 0/±10V (24V/20mA) isolated isolated output 2 x 0/±10V supply 24VDC (20.. 30V) isolated
View product
POSI CAL
Digital simulator of the position in % (0.. 100%) of the potentiometric value (3 wires).. Light and autonomous Digital setpoint by means of preselectors
View product
AMPER-BI-Relay-5S/15S
2-intensity deviation current relay at the input
View product
CV-0x Flowmeter
Vortex flowmeter with temperature and pressure compensation
View product
ISO 42R THERMOS
Wirelessly configurable Thermocouple and RTD to 4/20mA Isolator Converter (Active/Passive)
View product
CPx500 Series
Angular displacement sensors, resistive
View product
ISO-DUO-10
3-way isolator input 0/10V, excitation (24V/20mA) isolated, output isolated 0/10V, Power 24VDC (20..30V) isolated * 2 channels *
View product
Temperature sensors with “S” cable
Range of temperature sensors with cable output, Pt100, Pt1000, thermocouples, NTC, PTC.
View product
NPR80G-x
Radar level sensor
View product
DPF-AOCO2
Analog-digital CO2 Controller Sensor, with ModBus RS485 communication, for OUTDOORS
View product
AQUA LUX-xxx family
Luminosity sensors (luxometers) for industrial and home automation use
View product
TPD-33x
Differential pressure transmitter/controller
View product
DPF-AN2TH
Analogue-digital humidity and temperature controller sensor with LED signalling, relay alarm, for indoor use.
View product
QUATTRO Cell
Universal converter for up to 4 load cells, in IP65 watertight box. Isolated inputs, with sensitivity adjustment for each cell. Multiple output: 0-4/20mA and ± 0/10V. Dual power supply: 24VDC and 115/230VAC.
View product
PROCESS Relay
Process relay v/i. Digital setpoint numerical preselectors
View product
AMPER-O-300
AC/DC (TRMS) current transformer to 4/20mA current loop, with isolation, high precision. 0/150A - 0/300A - -150/+150A - -300/+300A
View product
SDTxx
Range of resistive displacement sensors, with different mounting options, with a range from 10 mm to 200 mm.
View product
BPSE
The BPSE load cell is used to measure compression forces in industrial applications, especially test benches. Measuring ranges from 500 kg to 350 tons.
View product
MUX8Tc-42R
Isolated multiplexer of 8 thermocouples to a 4/20mA output (Active / Passive)
View product
ISO2-V/42R
Universal 2-way galvanic isolator/converter. Input Programmable ranges (0/10.. 1000V), Output 0-4/20mA (Active / Passive) automatic, Power supply: 10...30 VDC
View product
DUPLO Pair and DUPLO Pair DUO
Insulated thermocouple duplicator J, K, T, E, N, R, S, B - To be able to connect 2 systems to a single thermocouple
View product
TRH070
Humidity and temperature sensor, for high temperature, -40...+180ºC
View product
AB-SUB Flowmeter
Electromagnetic flowmeter, with 4-20 mA and pulse output signal, optional HART or ModBus communication, pipes up to DN1200, clamp or flange mounting.
View product
THERMO-4Pt/2R
4 Pt100 sensor controller with 2 relay alarms
View product
XCA-xx-x
INCLINOMETER RANGE (±) 10°/360°/ To be specified, 1 or 2 axes, PRECISION: ±0.2º, RESOLUTION: 0.1º, special solar sector.
View product
THERMO-RTD (family)
Wirelessly configurable RTD to 4/20mA converter (Active/Passive)
View product
ANEMO-Relay.M12
Anemometer with direct alarm output (adjustable) with relay switching contact. Also available with 4...20 mA output.
View product
DUPLO 20-IN
Duplicator - 4/20mA signal isolator, *** INPUT: ACTIVE/PASSIVE *** OUTPUTS: 2X 4/20mA active, 24VDC (20.. 30V) isolated
View product
EXPAN8Pt ISO
Expansion of 4 or 8 Pt100 probes for the MUX8Pt-ISO
View product
TPS30
Submersible pressure level sensor, up to 150 meters of water column
View product
VOLTAGE Relay
Voltage supervisory relay (VAC). Overvoltage and undervoltage.
View product
HEAD-RTD-V
Wirelessly configurable RTD to 0/10V converter in chip format
View product
AMPER-O-RS-300
AC/DC to RS485 Modbus + 0/10V current transformer, with isolation, high precision. Range up to 300 amp.
View product
QUADRUPLUS-pot-Plus
Quadrupler - potentiometer signal isolator potentiometer input isolated output 4 x 4/20mA (Active / Passive) + 4 x 0/10V, with power regulation adjustment: 24.. 230VAC-DC (±15%) isolated
View product
LOGIC(+).3P-DUO
2 channels of Logic Function (+) OR of 2 signals
View product
ADAPTA DUO-D
Adapts and DUPLICATEs digital signals from one type and/or level to another
View product
ISO-AC/DC
True RMS AC/DC universal voltage and current isolator
View product
RX-3005DS
Variable power supply for laboratory tabletop 0/30V (5A)
View product
PE-01
Static torque sensor, ranges up to 10000 Nm, with 2mv/v output signal
View product
ISO-QUATTRO-10/42
Isolator-converter to active output 4/20mA, Input: 4 x 0-10 Vdc, Isolated output 4 x 0-4/20mA active, Power supply: 24VDC (20.. 30V) isolated, 4 channels in the same box.
View product
MEDIA-4xRTD/42R
Converter for averaging 4 RTD signals to 4/20mA
View product
ECO510 (family) Pixys
Profibus or Profinet gateways to RS485 Modbus and CANopen gateway to Profibus or Profinet
View product
xPT-xxx
Indoor or outdoor wall-mounted temperature sensors, with Pt100 signal, 4-20 mA, 0-10 Vdc, with or without display
View product
INTEGRATOR PLUS
Voltage/current/potentiometer to frequency converter, or PWM
View product
IND32-C
COUNTER indicator, 32 x 74 format. Input for encoders, inductive detectors, contacts,....
View product
PTC-Relay
Universal PTC trip temperature protection relay
View product
DPF-MITH
Indoor humidity and temperature sensor with RS485 ModBus communication
View product
ISO2-42P
Isolator for passive collectors. Passive output 4/20mA, input: 4/20mA (for passive pickup)
View product
ISO2 (V) Plus
Universal 2-way galvanic converter/isolator. Input: 0... 500 mV, 0... 700 V, (solar space up to 1500 V) / 20 mA, PWM, adjustable output (max. 5mA) 0/24Vdc for control 6/12/18Vdc.. others, 24VDC power supply (20..30V range)
View product
ECO-420-ETH
Converter with input: 4/20mA (active/passive), output: Ethernet (TCPServer, UDP, MQTT..)
View product
ISO-M10
3-way isolator input ± 0/10V, excitation (24V/20mA) isolated, output isolated ± 0/10V, Power supply 24VDC (20.. 30V) isolated
View product
MUX4Pt-3 and MUX8Pt-3
Multiplexer with 4 or 8 3-wire Pt100, Pt1000 probes at the output of the same probe
View product
RTD-DUPLO-20
4/20mA RTD Duplicator-Isolator (Active/Passive)
View product
ECO-TTL
RS232 to TTL/CMOS Bi-directional Converter (5V)
View product
DP-095
Anti-solar radiation protector
View product
CTC
Universal traction-compression load cell, from 15 to 5000 kg. 2 mv/v.
View product
ANEMO-PUL.M12
Anemometer with pulse output, proportional to wind speed, industrial use
View product
TERMOCAL (family)
Pt100 / Pt1000 / NTC / PTC temperature value generator (24 values with maximum error of 0.08%)
View product
IND32-R
CHRONOMETER indicator, 32 x 74 format. Simple or cyclic timer. Precision timer
View product
POWER mini Relay2
NPN/PNP sensor power supply to relay, adapter from PNP/NPN to potential-free contact output
View product
MULTI Test
Portable digital multimeter. MEASURES mA, mV, V, A, Hz, Ohm, uF, ºC (AC/DC).
View product
ECO-RS-Plus+
RS232 - RS485 - RS232 isolator-repeater converter
View product
POSI Plus
Universal converter for potentiometric type position sensors (100 Ohm/500Kohm) Multiple output: 0-4/20mA, 0/10V and ± 0/10V. Power supply: 24.. 230VAC-DC (±15%) isolated
View product
DUPLO 10
Duplicator - signal isolator 0/10V (with excitation) input: 0/10V excitation (24V/20mA) isolated isolated output 2 x 0/10V supply 24VDC (20.. 30V) isolated
View product
DPF-MIC02
NDIR sensor CO2 controller (4000 ppm) RS485 output with LED signaling
View product
DANA12 Flex
12-bit digital/analog converter.
View product